Dyna-Glo TT15CDGP Manuel d'utilisation et d'entretien Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
1. Stop! Read all safety information rst.
2. Open cylinder valve by turning counterclockwise
.
WARNING: 

3. Turn heater regulator knob counterclockwise to “OFF” ( ) position.
4. Wait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas,
STOP! Follow the safety information on the tag attached to the heater. If you do not smell gas, go to
the next step.
5. Turn heater regulator knob clockwise
to “High” ( ) position. Press in safety shut-off valve plunger.
(Fig. 5)
6. With safety shut-off valve plunger pressed in, immediately push down and release piezo ignitor button
repeatedly. This will light the burner.
7. Keep safety shut-off valve plunger pressed in for thirty (30) seconds after lighting. After 30 seconds,
release safety shut-off valve plunger.
8. If burner goes out, repeat steps 5 through 7 or use a match. If heater will not light after repeated attempts
do not attempt to repair heater.
9. When burner is lit, turn heater regulator knob to desired heat setting “LOW” ( ), “MED” ( ), or “HIGH” ( ).
10. On dual burner models light both burners when maximum heat is needed.
Use one burner to conserve fuel.

TURNING OFF THE HEATER
1. Tightly close propane tank valve by fully turning clockwise .
2. Turn the heater regulator knob to the “OFF” (
) position. Wait at least 30 minutes for the heater to cool
before handling heater.
3. Always remove the heater from the propane tank after each use and store indoors. Do not store heater while
attached to propane tank. Do not store propane cylinders in a building, garage or any other enclosed area.
VENTILATION
Always be sure to supply proper ventilation while operating this heater.
Provide a minimum of 1/2 square foot opening for fresh air supply for 15,000 BTU’s
of heat and one square foot opening for 30,000 BTU’s of heat.
13
PROPANE TANK TOP HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 20

Commentaires sur ces manuels

Pas de commentaire