Check all gas connections with a 50/50 soap and water solution to be sure they are tight and leak proof.
The formation of bubbles indicate a gas leak. Correct all leaks before using the heater.
• The installation of your heater must meet all local codes and/or gas utility requirements or, in the absence of
local codes, with the Storage and Handling of Liqueed Petroleum Gases, ANSI/NFPA 58 and the Natural
and Propane Installation Code, CSA B149.1.
• The minimum clearances to combustible construction: Side and Rear- 36” (91cm); Top - 36” (91cm);
Front - 60” (150cm); Floor - combustible, must be maintained at all times. Not for use on nished oors.
• The hose assembly should be visually inspected prior to each use of the heater. If it is evident that there is
excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation.
• The replacement hose assembly shall be that specied by the manufacturer.
CHECKING FOR LEAKS
WARNING: Never use an open ame to check for leaks.
OPERATION - LIGHTING INSTRUCTIONS WHEN USING MATCH
WARNING:
WARNING:
WARNING:
WARNING:
9 10
PROPANE TANK TOP HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!