Dyna-Glo RMC-KFA120T Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
15
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
I.) PUMP PRESSURE ADJUSTMENT
- Remove pressure gauge plug from end filter cover.
- Install accessory pressure gauge.
- Start heater (See Operation, page 8)
Allow motor to reach full speed
- Adjust pressure (Using a flat blade screwdriver)
Turn relief valve to right to increase pressure. Turn
relief valve to left to decrease pressure. Set pump
pressure below correct for pressure for each model.
- Stop heater (See Operation, page 9)
- Remove pressure gauge. Replace pressure gauge
plug in end filter cover.
NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.
Use of alternate or third party components will void any warranty and may cause unsafe
operation condition.
Pressure Gauge
Plug
Relief Valve
Pressure Gauge
MODEL PUMP PRESSURE
RMC-KFA45T 2.8 psi
RMC-KFA65T 3.5 psi
RMC-KFA120T 4.5 psi
RMC-KFA170T 6.5 psi
RMC-KFA210T 8.5 psi
Vue de la page 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 27 28

Commentaires sur ces manuels

Pas de commentaire