Dyna-Glo RMC-TT15P Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Chauffages d'appoint Dyna-Glo RMC-TT15P. Dyna-Glo RMC-TT15P Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 10
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Printed in China
Dyna-Glo
®
Delux Natural
Gas Construction Heater
Operating Instructions & Parts Manual RMC-FA150NGDGD
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
Description
Dyna-Glo Delux model RMC-FA150NGDGD is a natural gas fired construction
heater, having a built-in thermostat, and a 150,000 BTU/Hr rating. The heater
uses natural gas for com bustion and electricity to operate the motor and fan.
It is primarily to be used to temporarily heat well-ventilated buildings under
construction, alteration or repair. This heater should be utilized in sheltered, well-
ventilated areas, but never in occupied dwellings.
Specifications
Figure 1 – Model RMC-FA150NGDGD
Manifold Maximum Supply Minimum Supply Temperature
Model Pressure Pressure to Heater Pressure to Heater Control
RMC-FA150NGDGD 4” W.C. 1/2 PSI 5” W.C. Built-In Thermostat
Spark Plug Ignitor Gap Weight Size
Model Ignition Gap (Inches) (Inches) (Pounds) L x W x H (Inches)
RMC-FA150NGDGD Continuous spark .12 .12 18.6 (Heater) 25 x 9.4 x 15.5
22 (Shipping)
E
N
G
L
I
S
H
E
S
P
A
O
L
F
R
A
N
Ç
A
I
S
PROFESSIONAL GRADE
Table of Contents Page
Description .......................1
Specifications......................1
Unpacking ....................... 1
General Safety Information ........1-3
Principals of Operation..............3
Ventilation........................3
Installation........................4
Operation ........................4
Maintenance ....................4-5
Storage ..........................5
Wiring Diagram....................6
Repair Parts Illustration .............7
Repair Parts List....................7
Troubleshooting Chart ..............8
Warranty .........................9
Unpacking
1. Unpack all materials used to protect
the heater inside of carton. Retain
plastic caps attached to exposed
fittings for use during storage.
2. Remove heater, accessories and all
hardware from carton.
3. Inspect all items for damage that may
have occurred during shipment.
General Safety Information
Make certain you read and understand
all warnings. Keep these instructions for
reference. They are your guide to safe
and proper operation of this heater.
Safety information appears throughout
these instructions. Pay close attention
to them. Below are definitions for the
safety information listed throughout
this manual.
DANGER
Indicates an
im minen tly
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
WARNING
Indicates a poten-
tially hazardous
situation which, if not avoided, COULD
result in death or serious injury.
CAUTION
Indicates a poten-
tially hazardous
situa tion which, if not avoided, MAY
result in minor or moderate injury.
IMPORTANT: Not every possible cir-
cumstance that might involve a hazard
can be anticipated. The warnings in this
manual and on tags or decals affixed to
the unit are therefore not all-inclusive.
If a procedure, work method, or oper-
ating technique not specifically recom-
mend ed by is used, you must make sure
it is safe for you and others.
You should also ensure that equipment
will not be damaged or made unsafe by
the operating or maintenance method
you choose.
Consumer: Retain this manual for future
reference.
Output Rating Fuel Hot Air Output Electric Motor
Model BTU/Hr Fuel Consumption (CFM Approx) Motor Input Amperage
RMC-FA150NGDGD 150,000 Natural Gas Only 146 Cubic Ft/Hr 435 3440 RPM 120V/60Hz, 1/9 HP 0.7
&86
CSA 2.14b-2009, ANS Z83.7b-2009 Construction Heater
Rev 2011-01-28
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - Gas Construction Heater

Printed in ChinaDyna-Glo® Delux Natural Gas Construction HeaterOperating Instructions & Parts Manual RMC-FA150NGDGDPlease read and save these ins

Page 2 - Construction Heater

WARRANTY REGISTRATIONIMPORTANT: We urge you to fill out your warranty registration card within fourteen (14)days of date of purchase. You can also reg

Page 3 - Model RMC-FA150NGDGD

General Safety Information (Continued)WARNINGGeneral Hazard Warn ing: Failure to comply with the precautions and instructions provided with this hea

Page 4

General Safety Information (Continued)– This heater is equipped with a thermo-stat. Heater may start at anytime.– Never move, handle, or service a h

Page 5

InstallationWARNINGReview and under-stand all of the warnings in the Safety Information Section on pages 1–3. They are required to operate this heater

Page 6

PROFESSIONAL GRADEMaintenance (Continued)2. Always keep heater clean. Clean the heater annually, or as often as needed to remove any dust or debris. W

Page 7 - RMC-FA150NGDGD

6Wiring DiagramsDyna-Glo Delux Operating Instructions and Parts ManualDyna-Glo® Delux Natural Gas Construction HeaterRMC-FA150NGDGDFor Technical Suppo

Page 8

7Dyna-Glo Delux Operating Instructions and Parts ManualRMC-FA150NGDGDFor Repair Parts, call 1-877-447-4768Please provide following information:-Model

Page 9

RMC-FA150NGDGDDyna-Glo Delux Operating Instructions and Parts ManualSymptom Possible Cause(s) Corrective ActionFan does not turn when electrical con

Page 10 - WARRANTY REGISTRATION

LIMITED WARRANTY:This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against

Commentaires sur ces manuels

Pas de commentaire